Performances Assessment of Wastewater Treatment Plant in Boujaâd City, Khouribga Province, Morocco

  • Kamal Ait Ouhamchich University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco
  • Abdelkrim Arioua University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco
  • Mustapha Lbayny National Office of Electricity and Drinking Water, Khouribga, Morocco
  • Ismail Karaoui University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco
  • Khalid El Habbari University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco
  • Abdelkhalek El Amrani Idrissi Oum Er-Rbia Hydraulic Basin Agency of Management, Beni Mellal, Morocco
  • Mohamed Hssaisoune University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco
  • Abdelali Boulli University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco
  • Driss Elhamdouni University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco
  • Fatima Ezzahra Elfiraoui University Sultan Moulay Slimane, Faculty of Sciences and Technologies, Beni Mellal, Morocco

Abstract

The wastewater purification is a complicated and costlier operation if it not well chosen. Contrariwise, it could be simple and cheaper if the treatment system respect the environmental conditions and under international standards. To purify its wastewater, Boujaâd City chose to use the natural lagooning system. To verify the ability of this system, our study focuses on assessing the performances of this system to purify Boujaad city wastewater. For this reason, this study is based on the physicochemical monitoring of raw and purified water, both spatially and temporally, to detect and determine the percentage of pollution abatement in this wastewater treatment plant. According to the results, the quality of wastewater treatment plant rejection is conforming to the national and international standards. Here, the biochemical oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids (SS) parameters reached 69%, 66%, and 86% respectively. The results obtained show that the purification operation in Boujaad wastewater treatment plant was adequate.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

PlumX Statistics

Published
2018-09-30
How to Cite
Ouhamchich, K. A., Arioua, A., Lbayny, M., Karaoui, I., Habbari, K. E., Idrissi, A. E. A., Hssaisoune, M., Boulli, A., Elhamdouni, D., & Elfiraoui, F. E. (2018). Performances Assessment of Wastewater Treatment Plant in Boujaâd City, Khouribga Province, Morocco. European Scientific Journal, ESJ, 14(27), 193. https://doi.org/10.19044/esj.2018.v14n27p193